1.1. KV SINGLE CORE ALIMINIUM CONDUCTOR, PVC INSULATED HARD DRAWN ALUMINIUM ARMOURED / UNAMOURED CABLES CONFORMING TO IS: 1554 (Part-1) |
|||||||||||||
Nominal Area of Conductor
|
UNARMOURED CABLES |
ARMOURED CABLES |
|||||||||||
Nominal Thickness of insulation |
Minimum Thickness of diameter of cable |
Approx. Weight of cable |
Approx thickness of insulation |
Nominal thickness of Insulation |
Nominal diameter Of amour Wire |
Minimum Thickness of outer sheath |
Approx. Weight of cable |
Approx. Weight of cable |
Nominal Diameter of amour strip |
Minimum thickness of outer sheath |
Approx overall diameter of cable |
Approx. weight of cable |
|
Sp. mm |
mm |
mm |
mm |
Kg/Km |
mm |
mm |
mm |
mm |
Kg/Km |
mm |
mm |
mm |
Kg/Km |
6 |
1.0 |
1.8 |
9.0 |
100 |
1.3 |
1.4 |
1.24 |
12.0 |
180 |
- |
- |
- |
- |
10 |
1.0 |
1.8 |
10.0 |
120 |
1.3 |
1.4 |
1.24 |
13.0 |
200 |
- |
- |
- |
- |
16 |
1.0 |
1.8 |
11.0 |
160 |
1.3 |
1.4 |
1.24 |
14.0 |
250 |
- |
- |
- |
- |
25 |
1.2 |
1.8 |
13.0 |
210 |
1.5 |
1.4 |
1.24 |
15.0 |
300 |
- |
- |
- |
- |
35 |
1.2 |
1.8 |
14.0 |
250 |
1.5 |
1.4 |
1.24 |
16.0 |
350 |
- |
- |
- |
- |
50 |
1.4 |
1.8 |
16.0 |
300 |
1.7 |
1.4 |
1.24 |
18.0 |
450 |
- |
- |
- |
- |
70 |
1.4 |
1.8 |
17.0 |
400 |
1.7 |
1.4 |
1.4 |
20.0 |
550 |
- |
- |
- |
- |
95 |
1.6 |
1.8 |
19.0 |
500 |
1.9 |
1.6 |
1.4 |
22.0 |
700 |
0.80 |
1.4 |
21.0 |
650 |
120 |
1.6 |
2.0 |
21.0 |
600 |
1.9 |
1.6 |
1.4 |
24.0 |
800 |
0.80 |
1.4 |
23.0 |
750 |
150 |
1.8 |
2.0 |
23.0 |
750 |
2.1 |
1.6 |
1.4 |
26.0 |
950 |
0.80 |
1.4 |
24.0 |
900 |
185 |
2.0 |
2.0 |
25.0 |
900 |
2.3 |
1.6 |
1.4 |
29.0 |
1100 |
0.80 |
1.4 |
27.0 |
1050 |
240 |
2.2 |
2.0 |
28.0 |
1100 |
2.5 |
1.6 |
1.56 |
32.0 |
1400 |
0.80 |
1.4 |
30.0 |
1300 |
300 |
2.4 |
2.0 |
30.0 |
1350 |
2.7 |
1.6 |
1.56 |
33.0 |
1650 |
0.80 |
1.56 |
32.0 |
1600 |
400 |
2.6 |
2.2 |
35.0 |
1700 |
3.0 |
2.0 |
1.56 |
39.0 |
2100 |
0.80 |
1.56 |
37.0 |
1950 |
500 |
3.0 |
2.2 |
38.0 |
2150 |
3.4 |
2.0 |
1.7 |
42.0 |
2700 |
0.80 |
1.56 |
40.0 |
2400 |
630 |
3.4 |
2.4 |
43.0 |
2750 |
3.9 |
2.0 |
1.88 |
48.0 |
3300 |
0.80 |
1.72 |
45.0 |
3100 |
800 |
3.4 |
2.4 |
48.0 |
3300 |
3.9 |
2.0 |
1.88 |
52.0 |
4000 |
0.80 |
1.88 |
49.0 |
3700 |
1000 |
3.4 |
2.6 |
52.0 |
4100 |
3.9 |
2.5 |
2.04 |
59.0 |
4900 |
0.80 |
2.04 |
55.0 |
4600 |
1.1. KV 3½ CORE ALIMINIUM CONDUCTOR, PVC INSULATED ARMOURED / UNARMOURED ALUMINIUM CABLES CONFORMING TO IS: 1554 (Part-1)
|
||||||||||||||||
|
UNARMOURED CABLES
|
ARMOURED CABLES
|
|||||||||||||||
| AYY
|
Single Layer – Wire (AYWY)
|
Single Srtip – Wire (AYFY)
|
||||||||||||||
Nominal Area of Conductor
|
Nominal thickness of Insulation Main/ Neutral
|
Minimum thickness of Inner sheath
|
Nominal thickness of outer sheath
|
Approx. overall diameter of cable
|
Approx. weight of cable
|
Nominal diameter of armour wire
|
Minimum thickness of outer sheath
|
Approx. overall diameter of cable
|
Approx. weight of cable
|
Nominal diameter of armour strip
|
Minimum thickness of outer sheath
|
Approx. overall diameter of cable
|
Approx. weight of cable
|
|||
Sp. mm |
mm |
mm |
mm |
Kg/Km |
mm |
mm |
mm |
mm |
Kg/Km |
mm |
mm |
mm |
Kg/Km |
|||
25 |
1.2/1.0 |
0.3 |
2.0 |
24.0 |
700 |
1.6 |
1.4 |
26.0 |
1300 |
0.8 |
1.40 |
24.0 |
1000 |
|||
35 |
1.2/1.0 |
0.3 |
2.0 |
26.0 |
850 |
1.6 |
1.4 |
28.0 |
1450 |
0.8 |
1.40 |
26.0 |
1200 |
|||
50 |
1.4/1.2 |
0.3 |
2.0 |
29.0 |
1050 |
1.6 |
1.56 |
31.0 |
1800 |
0.8 |
1.56 |
30.0 |
1500 |
|||
70 |
1.4/1.2 |
0.4 |
2.2 |
32.0 |
1400 |
2.0 |
1.56 |
36.0 |
2400 |
0.8 |
1.56 |
34.0 |
1800 |
|||
95 |
1.6/1.4 |
0.4 |
2.2 |
36.0 |
1800 |
2.0 |
1.72 |
39.0 |
3000 |
0.8 |
1.56 |
37.0 |
2300 |
|||
120 |
1.6/1.4 |
0.5 |
2.4 |
40.0 |
2200 |
2.0 |
1.88 |
43.0 |
3500 |
0.8 |
1.72 |
41.0 |
2800 |
|||
150 |
1.8/1.4 |
0.5 |
2.4 |
44.0 |
2600 |
2.0 |
1.88 |
47.0 |
4000 |
0.8 |
1.88 |
45.0 |
3200 |
|||
185 |
2.0/1.6 |
0.5 |
2.6 |
48.0 |
3200 |
2.5 |
2.04 |
53.0 |
5200 |
0.8 |
2.04 |
49.0 |
3900 |
|||
240 |
2.2/1.6 |
0.6 |
3.0 |
54.0 |
4100 |
2.5 |
2.36 |
58.0 |
6400 |
0.8 |
2.20 |
55.0 |
4800 |
|||
300 |
2.4/1.8 |
0.6 |
3.2 |
62.0 |
5000 |
3.15 |
2.52 |
66.0 |
8200 |
0.8 |
2.36 |
61.0 |
5800 |
|||
400 |
2.6/2.0 |
0.7 |
3.4 |
68.0 |
6300 |
3.15 |
2.68 |
75.0 |
9900 |
0.8 |
2.68 |
69.0 |
7300 |
|||
500 |
3.0/2.2 |
0.7 |
3.8 |
77.0 |
8000 |
4.0 |
3.00 |
84.0 |
13500 |
0.8 |
2.84 |
77.0 |
9000 |
|||
630 |
3.4/2.4 |
0.7 |
4.0 |
87.0 |
10000 |
4.0 |
3.00 |
92.0 |
1600 |
0.8 |
3.00 |
87.0 |
11500 |
|||
| 1.1. KV 1.5 Sp. mm. STANDARD CONDUCTOR, PVC INSULATED ARMOURED / UNARMOURED COPPER CONTROL CABLES CONFORMING TO IS: 1554 (Part-1) | ||||||||||||||||
UNARMOURED CABLES ARMOURED CABLES |
||||||||||||||||
|
||||||||||||||||
Number of Cores |
Nominal thickness of Insulation |
Minimum thickness of Inner sheath |
Nominal thickness of outer sheath |
Approx. overall diameter of cable |
Approx. weight of cable |
Nominal diameter of armour wire |
Minimum thickness of outer sheath |
Approx. overall diameter of cable |
Approx. weight of cable |
Nominal diameter of armour strip |
Minimum thickness of outer sheath |
Approx. overall diameter of cable |
Approx. weight of cable |
|||
mm |
mm. |
mm. |
Kg/Km |
Mm |
mm |
mm |
mm |
Kg/Km |
mm |
mm |
mm |
Kg/Km |
||||
2 |
0.8 |
0.3 |
1.8 |
12 |
180 |
1.4 |
1.24 |
14 |
420 |
- |
- |
- |
- |
|||
3 |
0.8 |
0.3 |
1.8 |
13 |
210 |
1.4 |
1.24 |
14.5 |
450 |
- |
- |
- |
- |
|||
4 |
0.8 |
0.3 |
1.8 |
14 |
250 |
1.4 |
1.24 |
15 |
500 |
- |
- |
- |
- |
|||
5 |
0.8 |
0.3 |
1.8 |
14 |
270 |
1.4 |
1.24 |
16 |
550 |
- |
- |
- |
- |
|||
6 |
0.8 |
0.3 |
1.8 |
15 |
300 |
1.4 |
1.24 |
17 |
600 |
- |
- |
- |
- |
|||
7 |
0.8 |
0.3 |
1.8 |
15 |
320 |
1.4 |
1.24 |
17 |
630 |
- |
- |
- |
- |
|||
8 |
0.8 |
0.3 |
1.8 |
16 |
370 |
1.4 |
1.24 |
18 |
700 |
- |
- |
- |
- |
|||
9 |
0.8 |
0.3 |
1.8 |
17 |
400 |
1.4 |
1.24 |
20 |
750 |
- |
- |
- |
- |
|||
10 |
0.8 |
0.3 |
1.8 |
19 |
450 |
1.4 |
1.4 |
21 |
845 |
- |
- |
- |
- |
|||
12 |
0.8 |
0.3 |
1.8 |
20 |
500 |
1.6 |
1.4 |
22 |
970 |
0.8 |
1.24 |
20 |
745 |
|||
14 |
0.8 |
0.3 |
1.8 |
20 |
550 |
1.6 |
1.4 |
23 |
1050 |
0.8 |
1.40 |
21 |
820 |
|||
16 |
0.8 |
0.3 |
1.8 |
21 |
600 |
1.6 |
1.4 |
24 |
1100 |
0.8 |
1.40 |
22 |
900 |
|||
19 |
0.8 |
0.3 |
2.0 |
23 |
700 |
1.6 |
1.4 |
25 |
1250 |
0.8 |
1.40 |
23 |
1000 |
|||
24 |
0.8 |
0.3 |
2.0 |
26 |
900 |
1.6 |
1.4 |
28 |
1500 |
0.8 |
1.40 |
27 |
1200 |
|||
27 |
0.8 |
0.3 |
2.0 |
27 |
950 |
1.6 |
1.4 |
29 |
1600 |
0.8 |
1.40 |
27 |
1300 |
|||
30 |
0.8 |
0.3 |
2.0 |
28 |
1050 |
1.6 |
1.4 |
30 |
1700 |
0.8 |
1.40 |
28 |
1400 |
|||
37 |
0.8 |
0.3 |
2.0 |
29 |
1240 |
1.6 |
1.4 |
32 |
1950 |
0.8 |
1.40 |
30 |
1600 |
|||
40 |
0.8 |
0.3 |
2.0 |
30 |
1300 |
1.6 |
1.56 |
33 |
2100 |
0.8 |
1.40 |
31 |
1750 |
|||
44 |
0.8 |
0.3 |
2.0 |
33 |
1450 |
1.6 |
1.56 |
35 |
2300 |
0.8 |
1.56 |
34 |
1900 |
|||
52 |
0.8 |
0.4 |
2.0 |
35 |
1700 |
2.0 |
1.56 |
38 |
2800 |
0.8 |
1.56 |
35 |
2150 |
|||
61 |
0.8 |
0.4 |
2.2 |
37 |
1950 |
2.0 |
1.56 |
40 |
3100 |
0.8 |
1.56 |
37 |
2400 |
|||
1.1. KV 2.5 Sp. mm. STANDARD CONDUCTOR, PVC INSULATED ARMOURED / UNARMOURED COPPER CONTROL CABLES CONFORMING TO IS: 1554 (Part-1) |
||||||||||||||||
UNARMOURED CABLES ARMOURED CABLES |
||||||||||||||||
|
||||||||||||||||
Number of Cores |
Nominal thickness of Insulation |
Minimum thickness of Inner sheath |
Nominal thickness of outer sheath |
Approx. overall diameter of cable |
Approx. weight of cable |
Nominal diameter of armour wire |
Minimum thickness of outer sheath |
Approx. overall diameter of cable |
Approx. weight of cable |
Nominal diameter of armour strip |
Minimum thickness of outer sheath |
Approx. overall diameter of cable |
Approx. weight of cable |
|||
Sp. mm |
mm |
mm. |
mm. |
Kg/Km |
Mm |
mm |
mm |
mm |
Kg/Km |
mm |
mm |
mm |
Kg/Km |
|||
2 |
0.9 |
0.3 |
1.8 |
13 |
240 |
1.4 |
1.24 |
15 |
500 |
- |
- |
- |
- |
|||
3 |
0.9 |
0.3 |
1.8 |
14 |
270 |
1.4 |
1.24 |
16 |
550 |
- |
- |
- |
- |
|||
4 |
0.9 |
0.3 |
1.8 |
15 |
320 |
1.4 |
1.24 |
17 |
620 |
- |
- |
- |
- |
|||
5 |
0.9 |
0.3 |
1.8 |
16 |
350 |
1.4 |
1.24 |
18 |
680 |
- |
- |
- |
- |
|||
6 |
0.9 |
0.3 |
1.8 |
17 |
400 |
1.4 |
1.24 |
20 |
750 |
- |
- |
- |
- |
|||
7 |
0.9 |
0.3 |
1.8 |
17 |
440 |
1.4 |
1.24 |
20 |
790 |
- |
- |
- |
- |
|||
8 |
0.9 |
0.3 |
1.8 |
18 |
500 |
1.4 |
1.4 |
21 |
950 |
- |
- |
- |
- |
|||
9 |
0.9 |
0.3 |
1.8 |
19 |
550 |
1.6 |
1.4 |
22 |
1050 |
0.8 |
1.40 |
21 |
840 |
|||
10 |
0.9 |
0.3 |
1.8 |
21 |
600 |
1.6 |
1.4 |
24 |
1150 |
0.8 |
1.40 |
22 |
900 |
|||
12 |
0.9 |
0.3 |
2.0 |
22 |
700 |
1.6 |
1.4 |
25 |
1250 |
0.8 |
1.40 |
23 |
1000 |
|||
14 |
0.9 |
0.3 |
2.0 |
24 |
800 |
1.6 |
1.4 |
26 |
1350 |
0.8 |
1.40 |
24 |
1075 |
|||
16 |
0.9 |
0.3 |
2.0 |
25 |
900 |
1.6 |
1.4 |
27 |
1450 |
0.8 |
1.40 |
25 |
1150 |
|||
19 |
0.9 |
0.3 |
2.0 |
26 |
1000 |
1.6 |
1.4 |
28 |
1620 |
0.8 |
1.40 |
26 |
1330 |
|||
24 |
0.9 |
0.3 |
2.0 |
30 |
1200 |
1.6 |
1.56 |
32 |
2000 |
0.8 |
1.56 |
30 |
1630 |
|||
27 |
0.9 |
0.3 |
2.0 |
31 |
1350 |
1.6 |
1.56 |
33 |
2100 |
0.8 |
1.56 |
31 |
1750 |
|||
30 |
0.9 |
0.3 |
2.0 |
32 |
1500 |
1.6 |
1.56 |
34 |
2250 |
0.8 |
1.56 |
32 |
1920 |
|||
37 |
0.9 |
0.4 |
2.2 |
34 |
1800 |
2.0 |
1.56 |
37 |
2900 |
0.8 |
1.56 |
35 |
2225 |
|||
40 |
0.9 |
0.4 |
2.2 |
36 |
1900 |
2.0 |
1.56 |
39 |
3100 |
0.8 |
1.56 |
36 |
2400 |
|||
44 |
0.9 |
0.4 |
2.2 |
38 |
2100 |
2.0 |
1.56 |
41 |
3350 |
0.8 |
1.56 |
37 |
2600 |
|||
52 |
0.9 |
0.4 |
2.2 |
40 |
2450 |
2.0 |
1.72 |
43 |
3700 |
0.8 |
1.56 |
41 |
2950 |
|||
61 |
0.9 |
0.4 |
2.2 |
43 |
2800 |
2.0 |
1.72 |
46 |
4200 |
0.8 |
1.56 |
43 |
3350 |
|||
1.1. KV SINGLE CORE ALIMINIUM CONDUCTOR, XLPE INSULATED HARD DRAWN ALUMINIUM ARMOURED / UNARMOURED CABLES CONFORMING TO IS: 7098 (Part-1) |
||||||||||||||||
UNARMOURED CABLES ARMOURED CABLES
|
||||||||||||||||
|
||||||||||||||||
Nominal area of conductor |
Nominal thickness of Insulation |
Minimum thickness of Inner sheath |
Nominal thickness of outer sheath |
Approx. overall diameter of cable |
Approx. weight of cable |
Nominal diameter of armour wire |
Minimum thickness of outer sheath |
Approx. overall diameter of cable |
Approx. weight of cable |
Nominal diameter of armour strip |
Minimum thickness of outer sheath |
Approx. overall diameter of cable |
Approx. weight of cable |
|||
Sq. mm |
mm |
mm. |
mm. |
Kg/Km |
mm |
mm |
mm |
mm |
Kg/Km |
mm |
mm |
mm |
Kg/Km |
|||
6 |
0.7 |
1.8 |
8.2 |
80 |
1.0 |
1.4 |
1.24 |
10.5 |
130 |
- |
- |
- |
- |
|||
10 |
0.7 |
1.8 |
9.2 |
100 |
1.0 |
1.4 |
1.24 |
11.5 |
160 |
- |
- |
- |
- |
|||
16 |
0.7 |
1.8 |
10.5 |
130 |
1.0 |
1.4 |
1.24 |
13.0 |
200 |
- |
- |
- |
- |
|||
25 |
0.9 |
1.8 |
12.0 |
180 |
1.2 |
1.4 |
1.24 |
14.0 |
300 |
- |
- |
- |
- |
|||
35 |
0.9 |
1.8 |
13.0 |
230 |
1.2 |
1.4 |
1.24 |
15.0 |
350 |
- |
- |
- |
- |
|||
50 |
1.0 |
1.8 |
15.0 |
300 |
1.3 |
1.4 |
1.24 |
17.0 |
420 |
- |
- |
- |
- |
|||
70 |
1.1 |
1.8 |
16.0 |
370 |
1.4 |
1.4 |
1.24 |
19.0 |
520 |
- |
- |
- |
- |
|||
95 |
1.1 |
1.8 |
18.0 |
460 |
1.4 |
1.6 |
1.4 |
22.0 |
650 |
0.80 |
1.4 |
21.0 |
600 |
|||
120 |
1.2 |
1.8 |
20.0 |
550 |
1.5 |
1.6 |
1.4 |
24.0 |
750 |
0.80 |
1.4 |
23.0 |
700 |
|||
150 |
1.4 |
2.0 |
22.0 |
620 |
1.7 |
1.6 |
1.4 |
25.0 |
850 |
0.80 |
1.4 |
24.0 |
800 |
|||
185 |
1.6 |
2.0 |
24.0 |
820 |
1.9 |
1.6 |
1.4 |
28.0 |
1000 |
0.80 |
1.4 |
26.0 |
950 |
|||
240 |
1.7 |
2.0 |
27.0 |
1000 |
2.0 |
1.6 |
1.4 |
30.0 |
1250 |
0.80 |
1.4 |
30.0 |
1200 |
|||
300 |
1.8 |
2.0 |
30.0 |
1200 |
2.1 |
1.6 |
1.56 |
33.0 |
1500 |
0.80 |
1.56 |
32.0 |
1400 |
|||
400 |
2.0 |
2.2 |
33.0 |
1550 |
2.4 |
2.0 |
1.56 |
38.0 |
1900 |
0.80 |
1.56 |
36.0 |
1750 |
|||
500 |
2.2 |
2.2 |
36.0 |
1900 |
2.6 |
2.0 |
1.56 |
41.0 |
2350 |
0.80 |
1.56 |
39.0 |
2150 |
|||
630 |
2.4 |
2.2 |
40.0 |
2400 |
2.8 |
2.0 |
1.72 |
46.0 |
2900 |
0.80 |
1.72 |
44.0 |
2700 |
|||
800 |
2.6 |
2.4 |
47.0 |
3000 |
3.1 |
2.0 |
1.88 |
51.0 |
3600 |
0.80 |
1.72 |
48.0 |
3350 |
|||
1000 |
2.8 |
2.6 |
51.0 |
3750 |
3.3 |
2.5 |
2.04 |
56.0 |
4600 |
0.80 |
1.88 |
54.0 |
4100 |
|||
1.1 KV THREE CORE ALIMINIUM CONDUCTOR, XLPE INSULATED ARMOURED / UNARMOURED CABLES CONFORMING TO IS: 7098 (Part-1) |
||||||||||||||||
UNARMOURED CABLES ARMOURED CABLES |
||||||||||||||||
|
||||||||||||||||
Nominal area of conductor |
Nominal thickness of Insulation |
Minimum thickness of Inner sheath |
Nominal thickness of outer sheath |
Approx. overall diameter of cable |
Approx. weight of cable |
Nominal diameter of armour wire |
Minimum thickness of outer sheath |
Approx. overall diameter of cable |
Approx. weight of cable |
Nominal diameter of armour strip |
Minimum thickness of outer sheath |
Approx. overall diameter of cable |
Approx. weight of cable |
|||
Sq. mm |
mm |
mm. |
mm. |
Kg/Km |
mm |
mm |
mm |
mm |
Kg/Km |
mm |
mm |
mm |
Kg/Km |
|||
6 |
0.7 |
0.3 |
1.8 |
16.0 |
330 |
1.40 |
1.24 |
18.5 |
650 |
- |
- |
- |
- |
|||
10 |
0.7 |
0.3 |
1.8 |
18.5 |
400 |
1.40 |
1.24 |
20.0 |
750 |
- |
- |
- |
- |
|||
16 |
0.7 |
0.3 |
1.8 |
18.0 |
400 |
1.60 |
1.40 |
20.5 |
800 |
0.8 |
1.24 |
19.0 |
590 |
|||
25 |
0.9 |
0.3 |
2.0 |
21.0 |
530 |
1.6 |
1.40 |
23.0 |
1000 |
0.8 |
1.40 |
21.0 |
800 |
|||
35 |
0.9 |
0.3 |
2.0 |
22.0 |
640 |
1.6 |
1.40 |
25.0 |
1200 |
0.8 |
1.40 |
23.0 |
950 |
|||
50 |
1.0 |
0.3 |
2.0 |
25.0 |
800 |
1.6 |
1.56 |
29.0 |
1450 |
0.8 |
1.40 |
26.0 |
1100 |
|||
70 |
1.1 |
0.4 |
2.0 |
30.0 |
1100 |
2.0 |
1.56 |
32.0 |
2000 |
0.8 |
1.56 |
29.0 |
1450 |
|||
95 |
1.1 |
0.4 |
2.2 |
32.0 |
1350 |
2.0 |
1.56 |
35.0 |
2350 |
0.8 |
1.56 |
32.0 |
1750 |
|||
120 |
1.2 |
0.4 |
2.2 |
35.0 |
1650 |
2.0 |
1.72 |
39.0 |
2750 |
0.8 |
1.56 |
35.0 |
2100 |
|||
150 |
1.4 |
0.5 |
2.4 |
39.0 |
2050 |
2.0 |
1.88 |
43.0 |
3250 |
0.8 |
1.72 |
40.0 |
2500 |
|||
185 |
1.6 |
0.5 |
2.6 |
43.0 |
2500 |
2.5 |
2.04 |
48.0 |
4200 |
0.8 |
1.88 |
44.0 |
3000 |
|||
240 |
1.7 |
0.6 |
2.8 |
49.0 |
3150 |
2.5 |
2.20 |
53.0 |
5100 |
0.8 |
2.04 |
50.0 |
3750 |
|||
300 |
1.8 |
0.6 |
3.0 |
53.0 |
3850 |
2.5 |
2.36 |
58.0 |
6000 |
0.8 |
2.20 |
54.0 |
4500 |
|||
400 |
2.0 |
0.7 |
3.2 |
59.0 |
4850 |
3.15 |
2.68 |
65.0 |
7950 |
0.8 |
2.52 |
60.0 |
5650 |
|||
500 |
2.2 |
0.7 |
3.6 |
66.0 |
6100 |
3.15 |
2.84 |
72.0 |
9500 |
0.8 |
2.68 |
66.0 |
6900 |
|||
630 |
2.4 |
0.7 |
3.8 |
73.0 |
7650 |
4.0 |
3.00 |
81.0 |
12600 |
0.8 |
2.84 |
74.0 |
8550 |
|||
1.1 KV 3½ CORE ALIMINIUM CONDUCTOR, XLPE INSULATED ARMOURED / UNARMOURED CABLES CONFORMING TO IS: 7098 (Part-1) |
||||||||||||||||
UNARMOURED CABLES ARMOURED CABLES |
||||||||||||||||
|
||||||||||||||||
Nominal area of conductor |
Nominal thickness of Insulation Main/Neutral |
Minimum thickness of Inner sheath |
Nominal thickness of outer sheath |
Approx. overall diameter of cable |
Approx. weight of cable |
Nominal diameter of armour wire |
Minimum thickness of outer sheath |
Approx. overall diameter of cable |
Approx. weight of cable |
Nominal diameter of armour strip |
Minimum thickness of outer sheath |
Approx. overall diameter of cable |
Approx. weight of cable |
|||
Sq. mm |
mm |
mm. |
mm. |
Kg/Km |
mm |
mm |
Mm |
Mm |
Kg/Km |
mm |
mm |
Mm |
Kg/Km |
|||
25 |
0.9/0.7 | 0.3 | 2.0 | 22.0 | 610 | 1.6 | 1.40 | 25.0 | 1100 | 0.8 | 1.40 | 23.0 | 900 | |||
| 35 | 0.9/0.7 | 0.3 | 2.0 | 24.0 | 730 | 1.6 | 1.40 | 27.0 | 1300 | 0.8 | 1.40 | 25.0 | 1050 | |||
| 50 | 1.0/0.9 | 0.3 | 2.0 | 27.0 | 920 | 1.6 | 1.56 | 30.0 | 1600 | 0.8 | 1.40 | 28.0 | 1250 | |||
| 70 | 1.1/0.9 | 0.4 | 2.2 | 31.0 | 1250 | 2.0 | 1.56 | 35.0 | 2200 | 0.8 | 1.56 | 32.0 | 1650 | |||
| 95 | 1.1/1.0 | 0.4 | 2.2 | 34.0 | 1550 | 2.0 | 1.56 | 38.0 | 2650 | 0.8 | 1.56 | 35.0 | 2000 | |||
| 120 | 1.2/1.1 | 0.4 | 2.2 | 38.0 | 1900 | 2.0 | 1.72 | 42.0 | 3150 | 0.8 | 1.72 | 39.0 | 2450 | |||
| 150 | 1.4/1.1 | 0.5 | 2.4 | 43.0 | 2300 | 2.0 | 1.88 | 46.0 | 3650 | 0.8 | 1.72 | 43.0 | 2850 | |||
| 185 | 1.6/1.1 | 0.5 | 2.6 | 46.0 | 2850 | 2.5 | 2.04 | 51.0 | 4750 | 0.8 | 1.88 | 48.0 | 3450 | |||
| 240 | 1.7/1.2 | 0.6 | 2.8 | 52.0 | 3600 | 2.5 | 2.20 | 56.0 | 5750 | 0.8 | 2.04 | 53.0 | 4300 | |||
| 300 | 1.8/1.4 | 0.6 | 3.0 | 57.0 | 4400 | 2.5 | 2.36 | 60.0 | 6750 | 0.8 | 2.20 | 57.0 | 5100 | |||
| 400 | 2.0/1.6 | 0.7 | 3.4 | 65.0 | 5600 | 3.15 | 2.68 | 71.0 | 9000 | 0.8 | 2.52 | 66.0 | 6450 | |||
| 500 | 2.2/1.7 | 0.7 | 3.6 | 73.0 | 7000 | 3.15 | 2.84 | 79.0 | 11000 | 0.8 | 2.68 | 74.0 | 7950 | |||
| 630 | 2.4/1.8 | 0.7 | 4.0 | 82.0 | 8900 | 4.0 | 3.00 | 88.0 | 14500 | 0.8 | 3.00 | 82.0 | 9900 | |||